服務(wù)熱線(xiàn)電話(huà)
400-6188-756
超聲波清洗機部件損壞的檢查要注意什么?
來(lái)源:http://www.filiunsub.com/ 時(shí)間: 2024-06-13 瀏覽次數: 0
1.保險損壞
1. Insurance damage
在超聲波清洗機開(kāi)機后如發(fā)現無(wú)電源顯示,無(wú)動(dòng)作,要看電源座內保險是否損壞。
If there is no power display or action after the ultrasonic cleaning machine is turned on, first check if the fuse inside the power socket is damaged.
分析與判斷:有可能是用戶(hù)接地線(xiàn)與火線(xiàn)或零線(xiàn)混用,并沒(méi)有接地(本機地線(xiàn)是與機器外殼相連接),還有可能是機器短路,元器件老化出現短路現象,導致保險損壞。
Analysis and judgment: It is possible that the user's grounding wire is mixed with the live or neutral wire and not grounded (the grounding wire of the machine is connected to the machine casing), or there may be a short circuit in the machine due to aging of components, resulting in damage to the insurance.
檢測和:拿出保險絲看,有無(wú)斷裂,用萬(wàn)用表通斷檔測量是否斷開(kāi),更換新器件。
Detection and solution: Take out the fuse and check if it is broken. Use a multimeter to turn on and off the gear to measure if it is broken. Replace with a new component.
2.換能器損壞
2. Damaged transducer
分析與判斷:可能因超聲波清洗機長(cháng)時(shí)間處于開(kāi)機使用狀態(tài),溫度會(huì )逐漸上升導致交替融化話(huà)能去脫落或話(huà)能去陶瓷部分斷裂。
Analysis and judgment: It may be due to the ultrasonic cleaning machine being in the on state for a long time, and the temperature will gradually rise, resulting in alternating melting that can remove detachment or ceramic part fracture.
檢測和:用搖表測量話(huà)能去的絕緣強度,絕緣強度在200M以下,已無(wú)法使用,須換新的換能器。因換能器的內部陶瓷也會(huì )由于長(cháng)期使用出現斷裂,不能正常工作。
Detection and solution: Measure the insulation strength that can be removed using a shaking table. The insulation strength is below 200M and cannot be used anymore. A new transducer needs to be replaced. Due to long-term use, the internal ceramic of the transducer may also break and fail to function properly.
3.功率管損壞
3. Power tube damage
分析與判斷:主板上的功率管會(huì )因為超聲波清洗機長(cháng)時(shí)間不間斷使用,或清洗液太少長(cháng)時(shí)間使用,功率管出現短路情況。
Analysis and judgment: The power transistor on the motherboard may experience short circuits due to prolonged uninterrupted use of the ultrasonic cleaning machine or prolonged use of too little cleaning solution.
檢測和:檔功率管在主板上連接時(shí),用萬(wàn)用表測量功率管兩側管腳的阻值,正常情況下應在22左右,拿下功率管后(與主板斷開(kāi)連接),測量其各個(gè)管腳間應是不通的。
Detection and solution: When connecting the power transistor to the motherboard, use a multimeter to measure the resistance value of the pins on both sides of the power transistor. Normally, it should be around 22. After removing the power transistor (disconnected from the motherboard), measure that there should be no connection between its pins.
4.穩壓管損壞
4. Damaged voltage regulator
分析與判斷:穩壓管的損壞一般是在功率管阻值小或短路后,開(kāi)機造成的,本身極少損壞。
Analysis and judgment: The damage to the voltage regulator is generally caused by the power transistor's low resistance or short circuit when turned on, and the damage itself is extremely rare.
檢測和:根據二極管特性,正向導通,反向截。用萬(wàn)用表二極管檔測量,正向阻值70左右,反向∞。如數值偏差過(guò)大或正向阻值也是∞,更換新穩壓管。
Detection and resolution: Based on the characteristics of the diode, conduct in the forward direction and cut off in the reverse direction. Using a multimeter diode range measurement, the forward resistance value is around 70 and the reverse resistance value is ∞. If the numerical deviation is too large or the positive resistance value is also ∞, replace the regulator with a new one.
5.橋的損壞(二極管整流電路)
5. Bridge damage (diode rectification circuit)
分析與判斷:同穩壓管狀況
Analysis and judgment: Same as the condition of the voltage regulator
檢測和:同樣根據二極管特性(橋本身是由二極管組成),
Detection and resolution: Based on the characteristics of the diode (the bridge itself is composed of diodes),
6.控制板的損壞(可調超聲波清洗機)
6. Damage to control board (adjustable ultrasonic cleaning machine)
分析與判斷:長(cháng)時(shí)間連續工作,元器件老化有關(guān),或者有時(shí)會(huì )滲入清洗液有關(guān)。
Analysis and judgment: Long term continuous operation is related to component aging, or sometimes may be related to the infiltration of cleaning solution.
檢測和:在機器不工作狀態(tài)下,斷開(kāi)控制板與主板的連接,把主板通電,如機器工作,則表示控制板損壞,需要更換。
Detection and resolution: When the machine is not working, disconnect the control board from the motherboard and power on the motherboard. If the machine is working, it indicates that the control board is damaged and needs to be replaced.
7.電感、隔離變壓器的損壞
7. Damage to inductors and isolation transformers
分析與判斷:由于超聲波清洗機長(cháng)時(shí)間工作,電感、變壓器屬于散熱元件,其本身有可能會(huì )因溫度過(guò)高二融化、燒毀,造成短路。
Analysis and judgment: Due to the long-term operation of the ultrasonic cleaning machine, the inductor and transformer are cooling components, which may melt or burn out due to high temperature, causing a short circuit.
檢測和:電感、變壓器的損壞,大多數情況下直觀(guān)能看出燒壞的痕跡,更換新器件。
Detection and resolution: Damage to inductors and transformers, in most cases, visible signs of burning, should be replaced with new components.
本文由碳氫清洗機友情奉獻.更多有關(guān)的知識請點(diǎn)擊:http://www.filiunsub.com真誠的態(tài)度.為您提供為的服務(wù).更多有關(guān)的知識我們將會(huì )陸續向大家奉獻.敬請期待.
This article is a friendly contribution from the hydrocarbon cleaning machine. For more related knowledge, please click: http://www.filiunsub.com Sincere attitude. We will provide you with comprehensive service. We will gradually contribute more relevant knowledge to everyone. Stay tuned
相關(guān)產(chǎn)品
相關(guān)文章
-
工業(yè)超聲波清洗機成為零配件清洗行業(yè)的“香餑餑”,憑的是什么? 2024-07-25
-
超聲波清洗機的原理是什么?超聲波清洗機能清洗什么東西? 2024-07-19
-
超聲波清洗機真的有用嗎?超聲波清洗機的優(yōu)缺點(diǎn)分析 2024-07-13
-
噴淋清洗機與超聲波清洗機該如何選擇? 2024-07-11
-
通過(guò)式噴淋清洗設備工藝流程 2024-07-09
-
超能超聲波清洗機在軸承生產(chǎn)中的清洗應用 2024-07-04
-
超聲波清洗機功率如何選擇? 2024-07-03
-
半自動(dòng)超聲波清洗機設備特點(diǎn) 2024-06-27
-
實(shí)驗室超聲波清洗儀使用說(shuō)明及注意事項 2024-06-24
-
超聲波清洗機的應用領(lǐng)域介紹 2024-06-19